LaserGas II OP Monitor

long distance monitoring in ambient air, production halls, and gas leak detection.
Distances of up to 1000 m

NEO Monitors LaserGas II Open Path (OP) Monitor is s a compact, high performance gas analyser for long distance monitoring in ambient air. Measurement lengths of up to 1000 m one way are possible. The OP Monitor utilizes a transmitter / reflector configuration to measure the average gas concentration along the optical line-of-sight. As option a self-contained, battery-powered version is available with a control keypad and a flash memory for data logging.

The monitor is installed on our proprietary x/y alignment platform (goniometer). Adapters for fixed installation on platforms or for tripod use are available. The instrument also includes a visible aiming laser and sighting optics for easy alignment even over long distances. Hoods for protection of the optical windows on transceiver and reflector side can be supplied.

Features

  • Unaffected by dust, fog, or rain down to 1% transmission
  • Up to 1000 m measurement path
  • No cross interference from moisture (or other gases)
  • Stable calibration, no zero drift
  • No moving parts, no consumables
  • ATEX and CSA certified

NOTE: Detection limits are specified as the 95% confidence interval for 100 m optical path (one way) and gas temperature / pressure = 25 oC / 1 bar abs. 
Also available are CO2, HCN, C2H2, C2H4, C3H6, CH3I, CH2O, CH2CHCl (VCM), C2H4O (EtO), CH2Cl2(DCM)
Dual Gas: NH3+H2O, HCl+H2O, HF+H2O, CO+H2O, CH4+CO2

Documentation

LG II OP CSA Certificate LG II OP CSA Certificate
LG II OP ATEX DNV Cat 2 LG II OP ATEX DNV Cat 2
LG II OP ATEX DNV Zone 1 LG II OP ATEX DNV Zone 1
LG II OP ATEX DNV Zone 2 LG II OP ATEX DNV Zone 2
LaserGas II OP Monitor LaserGas II OP Monitor

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2026 - Ankersmid Group