Gas Sample Probe
Series ASP
Versie ASP 300, ASP
400, ASP 500,
Version
ASP 300, ASP 400, ASP 500,
·
Eletronsiche
verwarming
Eletronsiche
heating
·
Retractable insteekbuis ,
voorfilter en/of insteekbuis vervangen zonder de probe te
demonteren
Retractable plug tube,
to filter and / or plug tube replaced without disassembling the
probe
·
Diverse opties, zoals bij
terugspoeling automatische afsluiting van sample gas. Various options, such as back
flushing automatic closure of gas sample.
·
Universele
toepassingen
Universal
Applications
·
Compact and modulair ontwerp
geschikt voor nagenoeg iedere meting Compact and modular design allows
virtually any measurement
·
Eenvoudige
montage
Easy
installation
·
Eenvoudig en goedkoop in
onderhoud
Easy and cheap
maintenance
·
Digitale
comminicatie
Digital
comminicatie
·
Gepatenteerd
ontwerp
Patented
design
Application
These probes are
designed for continuous sampling from easy to very difficult process, from low
to extremely high dust levels, temperature or pressure.
Description
The simplest probe
can be applied to 1 g dust / m³ and the expanded combined with dust can easily
filter for applications along with 20 g dust / m³
Various options can
be selected by back flushing, other flange sizes / materials
Outputs
Via the controller
output signals are available as options and RS 485/modbus.
Most common
options
·
Indicating the
probe span va
·
Locking ball valve
or not in combination with automatic calibration / back flush
·
Back flushing with
high dust loads
Technical
Data
|
Gas Sample Probe
Version
|
ASP
30X
|
ASP
40X
|
ASP
50X
|
|
Length of
integrated filter
|
150mm
|
200mm
|
500mm
|
|
Integrated back
flushing
|
Available
|
|
Beschermingskap
|
Yes
|
|
Protection
class
|
IP55
EN60529
|
|
Materials in
contact with gas
|
Stainless steel
316L
|
|
seals
|
® for 180°C and
Grafiet voor 320°C uitvoering
FPM
/ Viton ® for 180 ° C and
320 ° C graphite performance
|
|
Plug Tube /
prefilter
|
Optional 200 or
500mm, stainless steel, 2μm or 20μm
|
|
Process pressure
max
|
0,5-6 bar
abs
|
|
ambient
|
-20 ° C to +65 °
C
|
|
Volume
baghouse
|
300
cm
³
|
480
cm
³
|
760
cm
³
|
|
Filter
Element
|
Ceramic, 2μm or
20 μm
|
316 stainless
steel, 2μm
|
316 stainless
steel, 2μm
|
|
Thermostatisering
|
0-180 ° C Pt 100
° C Optional 0-320 Fe-CuNi
|
|
Electronic
regulator
|
Digital
programmable PID controller with optional RS485 Modbus
|
|
temperature
alarm contact
|
Free
programmable contact, rating: 250V, 3A ~, Set to:? T 20 °
C
|
|
Sample gas
output
|
1x 1 / 4
"NPTi
|
|
Test gas
connection
|
1 / 4
"NPTi
|
|
Teruigspoel
connection
|
1 / 4
"NPTi
|
|
Voeding Nutrition
|
180°C 180 °
C
|
230VAC /
800W
115VAC /
800W
|
|
230VAC/1500W
115VAC/1500W
|
|
320°C 320 °
C
|
230VAC /
1100W
115VAC /
1100W
|
230VAC/1500W
115VAC/1500W
|
230VAC/1800W
115VAC/1800W
|
|
Electrical
connections
|
Terminals max
4mm2, 2x PG 13.5 connector
|
|
Standard
electrical equipment
|
EN 61010, EN
60519-1
|
|
Mounting
flange
|
DN65 PN6-B,
SS316L, other sizes / materials on request
|
|
Weight
|
16
kg
|
19
kg
|
24
kg
|
|
|
|
|
|
|
|
|
? P to
flow:
|
100
|
200
|
500
|
1000
|
1500
|
Nl /
hour
|
|
? P with new
filter element 2μ 150mm
|
0.009
|
0.013
|
0.025
|
0.055
|
0.090
|
bar
|
|
? P with new
filter element 2μ 250mm
|
0.005
|
0.010
|
0.018
|
0.030
|
0.050
|
bar
|
|
? P with new
filter element 2μ 500mm
|
0.002
|
0.004
|
0.010
|
0.015
|
0.025
|
bar
|
|
|